Updated October 2026
Pool Cover Box and Housing
Water standing in a pool cover housing damages the mechanism and the deck joint around the lid. A pool cover box is the pit or the bench that stores the roller, and each inside dimension stays on the sheet that printed it.
A pool cover box is the housing for the roller, the rolled fabric, and the mechanism. Cover-Pools places that mechanism recessed below the deck or housed on top of the deck. Coverstar's Concrete Cover Housing sheet prints a concrete pit 14 in. wide and 14 in. deep for pools up to 55 ft long or up to 25 ft wide, and 16 in. by 16 in. for longer pools, measured from the top of the bond beam or the top of the encapsulation. Cover-Pools overview 800024 prints a separate box for each mechanism: Save-T 3 with underside track on printed page 7, Save-T 3 with a deck-mounted track on printed page 10, and Autosave only for pools up to 13 ft or 200 square feet on printed pages 8 and 9.

| Input or item | Typical value or source | Why it matters |
|---|---|---|
| Coverstar concrete inside size, Concrete Cover Housing sheet | 14 in. wide by 14 in. deep for pools up to 55 ft long or up to 25 ft wide. Longer pools: 16 in. by 16 in. Depth is measured from the top of the bond beam or the top of the encapsulation. | That pair is the paragraph on the concrete sheet. The minimum-size grid on the same sheet is a separate table. |
| Coverstar end offsets, same sheet | Motor end 36 in. from the inside edge of the pool wall, 32 in. minimum. Non-motor end 12 in. | The drawing is shown motor-left and says the motor can sit on either side. |
| Coverstar drain and depth, Cover Housing Drainage sheet | Drain diameter 3 in. minimum, stated as 3,000 GPH. The sheet calls a 4 in. schedule 40 bottom exit, stated as 6,000 GPH, the best drain. Housing depth never under 14 in. | The 3 in. minimum and the 4 in. preference are both on this sheet. |
| Cover-Pools recessed housing, 800024 printed page 3 | Over-dig the cover-box end 18 in. beyond the forms. Keep plumbing 14 in. away from the deck in the housing area. Place a 3 in. drain in the floor or wall. | Printed page 4 says a recessed mechanism with a deck-mounted track uses these same requirements. |
| Cover-Pools Save-T 3 underside box, printed page 7 | Pools under 55 ft long by 24 ft wide: motor end 32 in., opposite end 10 in., depth 12-1/2 in. minimum, width 12-1/2 in. minimum. | Pools over 55 ft long by 24 ft wide on that table go to 14-1/2 in. minimum depth and width. |
| Cover-Pools Autosave box, printed pages 8 and 9 | The table is labeled up to 13 ft or 200 square feet. Motor-behind depth is 9 in. minimum and width is 12-1/2 in. minimum. | That table sizes Autosave. It does not size the Save-T 3 box on printed page 7. |
Coverstar prints the concrete pit on one sheet
The build sequence around this pit is the installation guide. The Concrete Cover Housing sheet says the walls are straight and plumb, the housing is square to the pool, and the housing walls match the pool wall. The inside for a standard housing is 14 in. wide and 14 in. deep from the side-wall bond-beam elevation, for pools up to 55 ft long or up to 25 ft wide. For longer pools the same paragraph says to make the housing 16 in. by 16 in. and to consult the Coverstar distributor. Coping and deck thickness vary, so housing depth on that sheet is always measured from the top of the beam or the top of the encapsulation.
The same sheet prints a minimum housing width and depth grid. Pool length is the row. Pool width is the column.
| Pool length | Up to 20 ft wide | Up to 25 ft wide | Up to 30 ft wide |
|---|---|---|---|
| 40 ft | 14 in. | 14 in. | 16 in. |
| 55 ft | 14 in. | 14 in. | 16 in. |
| 65 ft | 15 in. | 15 in. | 17 in. |
| 80 ft | 16 in. | 16 in. | 18 in. |
A 30 ft wide pool at 40 ft long is the 16 in. cell. The short paragraph above the drawing does not print that cell. Use the cell that matches both length and width, and keep the paragraph's instruction to consult the distributor for a longer pool.
The motor-end offset on that drawing is 36 in. from the inside edge of the pool wall, with 32 in. as the minimum. The non-motor end is 12 in. The lowered bond beam is 2 in. lower for screw-on guide applications and 1 in. lower when the bond beam is notched for encapsulation. Housing walls are 12 in. thick. The sheet calls for a minimum 3 in. diameter drain, stubbed before gunite, and for conduit or hose chase through the motor-end wall 3 in. below the top.
Coverstar Standard Topguide Installation Guide, printed page 8, places the housing in the deck. The guides start flush with the inside of the cover housing, "which must be a minimum of 12 inches from the end of the pool and extend 18 inches beyond the other end of the pool." The deck around the cover housing boxes should be flat for a minimum of 4 in. before any slope when a standard lid is used. For a flush deck lid, the deck is lowered 2 in. between the guides and the box is installed 2 in. lower. The same page recommends a minimum of 5 to 6 in. of concrete on each side of the housing. The recessed-horizontal option on that page starts the bend 15 in. in front of the housing and keeps the top of the guide a minimum of 1 in. lower than the bottom of the lid. Lid structure for that drop is on lid options. The guide that slopes into this pit is the recessed top track guide.

Cover-Pools prints one box table per mechanism
Which table applies follows the track. The track systems guide is the parent page for that choice. An underside track uses the housing on 800024 printed page 7. A guide under the coping is the undertrack guide.
Printed page 3 is the excavation list for a recessed mechanism with underside track or track channel. Over-dig the recessed cover box end 18 in. beyond the forms. Do not install plumbing within 14 in. of the deck in the housing area. The motor can be on either end. Place a 3 in. drain in the floor or wall of the recessed housing. The drawing marks excavation 36 in. from the waterline on the motor side and 18 in. and 16 in. from the waterline on the opposite side. Those marks are the excavation. They are not the inside width of the Coverstar concrete pit.
Printed page 4 says the requirements of a recessed mechanism with a deck-mounted track are the same as the undertrack on the previous page. Its drawing adds a 1 ft minimum setback at the mechanism, tracks extending 2 ft beyond the pool, and excavation of 18 in. and 16 in. on the non-motor side and 36 in. on the motor side.
Printed page 7 is the underside-track box for Save-T 3. Conduit stays on the motor end, protrudes no more than 4 in. into the box, and stays within 6 in. of the top of the box. The 3 in. drain can be on either end, with the drain centerline a maximum of 4 in. from the end wall. The side view calls for a minimum 2 in. clearance for the tracks.
| Save-T 3 underside box, printed page 7 | Motor end | Opposite end | Depth minimum | Width minimum |
|---|---|---|---|---|
| Pools under 55 ft long by 24 ft wide | 32 in. | 10 in. | 12-1/2 in. | 12-1/2 in. |
| UPB box, pools up to 55 ft long | 32 in. | 10 in. | 13 in. | 13 in. |
| Pools over 55 ft long by 24 ft wide | 32 in. | 10 in. | 14-1/2 in. | 14-1/2 in. |
Pools over 65 ft long or 25 ft wide, and vanishing-edge pools, are the line on that page that says to call Cover-Pools. Printed page 10 repeats this Save-T 3 table for a deck-mounted track and adds the bench: an Everlast bench kit with a maximum height of 20 in. by 24 in. wide. The existing-pools page is the plain-language version of that split. The mechanism can be recessed below the deck or housed on top of the deck. On the deck, the Everlast bench covers the mechanism. Below the deck, the mechanism sits in an enclosure, which works best when chosen before construction and can still be cut in later if the deck has room. That page does not print the cut depth.
Printed pages 8 and 9 are Autosave, and the table header is "Up to 13' or 200 square feet." Motor-behind: motor end 9 in. minimum, opposite end 9 in. minimum, depth 9 in. minimum, width 12-1/2 in. minimum. Motor-behind with auto-shutoff: motor end 14-1/2 in. minimum, depth still 9 in. minimum, width still 12-1/2 in. minimum. Motor-below: motor end 12-1/2 in. minimum, depth 9 in. minimum, width 12-1/2 in. minimum. Motor-below with auto-shutoff: width 14-1/2 in. minimum. Conduit on those pages protrudes no more than 4 in. into the box. Averaging this table with the 32 in. motor end on printed page 7 produces a box that neither page prints.
Every 800024 sheet used here carries the footer line that the diagrams are general information and that the installation instructions govern the details.
The drain leaves the housing on the sheet that sized it
Coverstar's Cover Housing Drainage sheet says to plan the drain before gunite. Drains must be 3 in. diameter, stated as 3,000 GPH, minimum. The sheet calls a 4 in. diameter schedule 40 bottom exit to daylight, stated as 6,000 GPH, the best drain. Drains go at the ends, where they can be serviced, rather than in the center. The floor may be pitched toward the drain for a total fall of 1-1/2 in. The same sheet says never make the housing less than 14 in. deep. Where the site has no slope, it says to elevate the finished pool 24 in. above the surrounding grade. If daylight is impossible, the sheet calls for a drywell or a pump-out pit. It rejects a french drain. A gravel pit fails when silt and debris clog the end of the drain. If the housing will also be the overfill drain, the sheet says it must handle a forgotten hose, stated as 600 to 1,500 GPH, or rainfall. The worked example below is that rainfall sentence.
Cover-Pools printed page 3, and the box drawings on printed pages 7, 8, and 10, place a 3 in. drain in the floor or wall. That 3 in. figure stays on those Cover-Pools pages. Coverstar's 4 in. preference stays on the drainage sheet. Coverstar's checklist, printed page 23 of the Standard Topguide Installation Guide, asks for adequate drainage from the cover housing and a box clean enough that the drains are not easily clogged. Cover-Pools' cover-care page says to check the drain in the recessed mechanism box and keep it free of debris. Water leaving the pit is the subject of the drainage requirements page.
Rule of thumb. If inside depth is under 14 in. on a Coverstar concrete housing, measured from the top of the bond beam or the top of the encapsulation, deepen the pit before the deck closes. The drainage sheet says never make the housing less than 14 in. deep, and the concrete housing sheet prints 14 in. as the inside depth for pools up to 55 ft long or up to 25 ft wide.
Worked example. The inputs are the ones printed on the Coverstar drainage sheet: a 20 by 40 pool left uncovered, and rain of 2 in. per hour. The sheet states that the drain would have to handle 1,000 GPH.
Gallons per hour = 20 * 40 * 2 / 12 * 7.48052
20 times 40 is 800 square feet. Two inches of rain is 2/12 of a foot, so the volume is 133.33 cubic feet. At 7.48052 gallons per cubic foot, that is 997 gallons in the hour. The sheet states 1,000 GPH for these inputs. The 20 ft, the 40 ft, and the 2 in. are the sheet's storm. They are not a pit depth.
The lid is the walking surface over that opening
Coverstar's lid compatibility sheet sorts the lid by whether anyone walks on it. A standard aluminum lid fits any housing and any deck and cannot be walked on. A flat lid cannot be walked on unless the brackets are upgraded to walk-on brackets at 36 in. spacing. A flush lid is for a concrete deck only, and it cannot be walked on unless extra brackets are added at 24 in. spacing. A walk-on lid is best on a concrete housing. The sheet says 2 in. thick material is recommended, with 24 in. bracket spacing, and that the builder is responsible for the strength. Lid stones must be at least as wide as the housing opening, 14 in. typical. Stones cannot extend more than 2 in. past the end of the brackets. Joints in the lid stones cannot sit within 6 in. of the guides. Stones over 100 lb, given as 2 in. by 14 in. by 48 in., raise the labor to install and service, and the sheet recommends 24 in. lengths.
Cover-Pools printed page 13 is the recessed-box lid. The maximum width of any tray is 24 in. The maximum length of a tray is 24 in. A vanishing-lid bracket labeled 12 in. is for a tray under 18 in. The 18 in. bracket is for trays 18 to 24 in. wide, with maximum bracket spacing of two feet. A walk-on vanishing lid requires a concrete housing or, with a wood housing, a concrete wall poured behind the box. Standard aluminum lids on that page are offered with a 4 in. or 6 in. hinge. Those hinge sizes stay on printed page 13.

What fails when the pit, the drain, and the lid are mixed
| Housing on its own page | Dominant failure mode and prevention |
|---|---|
| Coverstar concrete pit, drainage sheet | A floor under 14 in. deep, or a drain under 3 in. Deepen to the 14 in. minimum and use at least the 3 in. drain, pitched 1-1/2 in. toward daylight, a drywell, or a pump-out pit. |
| Cover-Pools recessed housing, printed page 3 | Plumbing inside the 14 in. deck zone, or no 3 in. drain. Over-dig 18 in. beyond the forms and keep plumbing 14 in. from the deck in the housing area. |
| Autosave box copied onto a Save-T 3 pool | A motor end taken from the 9 in. row instead of the 32 in. row. Use printed pages 8 and 9 only up to 13 ft or 200 square feet. Use printed page 7 for Save-T 3 underside track. |
| Walk-on stones, Coverstar lid sheet | A stone narrower than the opening, or a joint within 6 in. of a guide. Keep stones at least as wide as the opening, 14 in. typical, and end them within 2 in. of the brackets. |
A housing that holds water costs a stopped cover and a service opening before the roller can turn again. A lid that is grouted shut costs a cut through the finished deck. This page does not price either repair. The next check for standing water is drainage requirements. The next check for the walking surface is lid options.
Takeaway: copy the inside size from the sheet that names the mechanism and the housing material.
Where these sheets stop
Coverstar lists Polymer Housing Installation as a separate file. The 14 in. and 16 in. inside sizes above are the Concrete Cover Housing sheet. Copy a concrete cell onto a polymer box only when the polymer sheet prints that cell.
The Autosave table stops at 13 ft or 200 square feet. The Save-T 3 tables send pools over 65 ft long or 25 ft wide, and vanishing-edge pools, to a call with Cover-Pools. The existing-pools page allows a recessed cut in a finished deck and does not print the depth of that cut.
Common questions
Does a hydraulic cover use a smaller housing?
Autosave printed pages 8 and 9 change the motor-end length when the motor is behind the box, below the box, or fitted with auto-shutoff, and only for pools up to 13 ft or 200 square feet. A Save-T 3 underside box on printed page 7 keeps a 32 in. motor end for the pools that table covers. Moving the power pack off the pool does not replace that 32 in. end with the 9 in. Autosave row.
Can an existing pool take a recessed housing?
Cover-Pools' existing-pools page says the mechanism can still be recessed if there is room to cut into the deck, and that the recessed enclosure works best when it is chosen before construction. The page does not print the cut depth. The inside size still comes from the mechanism table: printed page 7 or 10 for Save-T 3, printed pages 8 and 9 for Autosave within 13 ft or 200 square feet.
Sources and method
Updated October 2026. This page explains the pool cover box from public manufacturer sheets. It is an independent technical account of those sheets. It is not a field test, a product ranking, or a substitute for the installation sheet that matches the mechanism on a given pool.
- Coverstar, Concrete Cover Housing, file 1104 on the Ellis documents list, fetched 17 October 2026. Inside 14 in. by 14 in. up to 55 ft long or 25 ft wide, 16 in. by 16 in. for longer pools, depth from the top of the beam or encapsulation, motor-end offset 36 in. (32 in. minimum), non-motor end 12 in., bond beam 2 in. or 1 in. lower, walls 12 in. thick, minimum 3 in. drain, conduit 3 in. below the top, and the length-by-width grid.
- Coverstar, Cover Housing Drainage, file 1107, fetched 17 October 2026. Drain 3 in. (3,000 GPH) minimum, 4 in. (6,000 GPH) preferred, never under 14 in. deep, 1-1/2 in. total fall, 24 in. elevation where the site has no slope, no french drain, and the 20 by 40 pool at 2 in. of rain per hour stated as 1,000 GPH.
- Coverstar, Standard Topguide Installation Guide, file 0903, fetched 17 October 2026. Printed page 8: the 12 in. and 18 in. housing sentence, 4 in. flat deck, 2 in. deck drop and 2 in. lower box for a flush deck lid, 5 to 6 in. of concrete each side, bend beginning 15 in. in front of the housing, guide top a minimum of 1 in. lower than the lid. Printed page 23: adequate drainage and a clean box.
- Coverstar, Lid options compatibility and considerations, file 1201, fetched 17 October 2026. Walk-on limits, 14 in. typical stones, 2 in. past the brackets, joints 6 in. from the guides, 2 in. material with 24 in. bracket spacing, and the 100 lb stone.
- Cover-Pools, General Installation Overview, 800024, fetched 17 October 2026. Printed page 3: 18 in. over-dig, 14 in. plumbing clearance, 3 in. drain, excavation marks. Printed page 4: deck-mounted track adopts the previous page, with the 1 ft setback and 2 ft track extension. Printed page 7: Save-T 3 underside box. Printed pages 8 and 9: Autosave up to 13 ft or 200 square feet. Printed page 10: deck-mounted Save-T 3 box and the 20 in. by 24 in. bench. Printed page 13: tray maximum 24 in. by 24 in. and the concrete housing for a walk-on vanishing lid.
- Cover-Pools, covers for existing pools, fetched 17 October 2026. Mechanism recessed below the deck or housed on top, Everlast bench, recessed enclosure when the deck can be cut. No cut depth is printed.
- Cover-Pools, cover care tips, fetched 17 October 2026. Check the drain in the recessed mechanism box and keep it free of debris.
The local industry library had no pool-cover housing manual for this topic. Cached search results had no stored SERP for this query. The pages above are the primary text.