Hydraulic Pool Cover System Design
A sharp bend in the hose pipe, or a hydraulic motor set below grade, leaks fluid at the housing and stops the cover. Hydraulic pool cover system design is the pump location, the hose path, and the motor height on Cover-Pools file 800024 Rel-0024, printed page 5.
Hydraulic pool cover system design, on Cover-Pools file 800024 Rel-0024 printed page 5, puts the hydraulic motor at the housing end and the pump unit on the far side of two 1/2 in. hoses. That hose callout applies when the run is over 80 ft. The pipe is 3 in. poly or PVC, with large sweeping bends and no sharp bends, and the motor stays above ground. The pump junction box is a dedicated GFCI with 2 identified wires and 1 ground, 14 AWG under 50 ft and 12 AWG over 50 ft. Printed page 16 adds 20 AMP for hydraulic at the panel. Printed page 14 lists a 1 1/2 hp/2000 PSI hydraulic system. Each figure below stays with the page that printed it.
| Input or item | Printed value or source | Why it stays on that page |
|---|---|---|
| System line, file 800024 printed page 14 | 1 1/2 hp/2000 PSI hydraulic system | Spec line for that Save-T sheet. Printed page 5 does not repeat the PSI |
| Unit label, printed page 6 | Hydraulic 1-1/2 hp motor, beside an electric 3/4 hp motor | The heading on that page says 3/4 hp motor or hydraulic motor. The drawing names 1-1/2 hp on the hydraulic unit |
| Hose callout, printed page 5 | two 1/2 in. hoses over 80 ft | The only hose size on that drawing |
| Hose size at 80 ft, and under 80 ft | The callout says over 80 ft. The equal case and the shorter case are blank | |
| Hose pipe, printed page 5 | 3 in. conduit for the hydraulic hose. 3 in. poly or PVC from housing to power unit. Large sweeping bends. NO SHARP BENDS | The path the hoses travel |
| Excavation row, printed page 16 | 3 in. conduit for hydraulic-unit housing | A checklist row. The file does not say it is a second pipe |
| Motor height, printed pages 5 and 6 | Hydraulic motors must be mounted above ground level | A motor below that line is outside the note |
| Drawing numbers, printed page 5 | 050275 or 050276, beside the hydraulic motor and the hydraulic pump unit | Printed as alternatives. The sheet does not assign one number to the motor and the other to the pump |
| Pump junction box, printed page 5 | 2 identified wires and 1 ground. 14 AWG under 50 ft. 12 AWG over 50 ft. Dedicated GFCI | The ampere figure on this callout is blank |
| Wire size at exactly 50 ft | The sheet prints under and over. The equal case is blank | |
| Panel row, printed page 16 | 15-amp GFCI dedicated circuit for the mechanism at the panel (20 AMP for hydraulic) | 20 AMP is the parenthesis. 15 amp is the mechanism row |
| Key switch KOSA, printed page 5 | Conduit with (3) 12 AWG minimum identified wires plus one ground | Separate from the pump feeder |
| CoverLink wired, printed page 5 | Conduit with (4) 18 AWG minimum identified wires | Control conduit, not the hose |
| Hydramatic fluid check, printed page 4 | Ideal level 2 in. below the cap | Bi-annual item 3. A different sentence from the fill line |
| Hydramatic fill, printed page 9 | Dexron-type automatic transmission fluid. Approximately 3.5 quarts. Within 1 to 2 in. of the top | That manual's reservoir. Not the Cover-Pools spec line |
The drive choice itself sits on hydraulic automatic pool covers.
Where do the pump and the motor sit?
Printed page 5 titles an optional Hydraulic Power System. The housing is marked HYDRAULIC MOTOR END. The pump is drawn as HYD PUMP UNIT, on the far side of the hose run. The note on the motor drawing says hydraulic motors must be mounted above ground level. Printed page 6 repeats that sentence and labels the unit Hydraulic 1-1/2 hp motor. The specifications on printed page 14 list 1 1/2 hp/2000 PSI hydraulic system. That PSI figure is the spec line. Printed page 5 does not print it again as a field setpoint.
The numbers 050275 or 050276 sit beside that motor and pump-unit drawing. They are printed as a pair of alternatives.
The housing still has a lid and a place for the roller. Those dimensions stay on the pool cover box and housing guide. The sleeve has to be in the ground before the deck closes, which is a hold point on the construction coordination guide.
What hose and pipe does printed page 5 name?
The callout beside the hose run reads two 1/2 in. hoses over 80 ft. A run over 80 ft is the length that callout names. A run of 80 ft, and any shorter run, has no hose size on this page.
The pipe is a separate callout. It reads 3 in. conduit for the hydraulic hose, with sweeping bends, and 3 in. poly or PVC from the housing to the power unit. The same callout says NO SHARP BENDS. Another label on the bend reads LARGE SWEEPING BENDS. Printed page 16, under excavation and plumbing, lists 3 in. conduit for the hydraulic-unit housing as its own row. The file does not print a sentence that the checklist row and the page 5 pipe are two pipes, or one pipe.
This sheet does not print a flow rate or a pressure-drop figure for that hose.
Which conductors feed the pump?
The pump junction box is its own conduit: 2 identified wires and 1 ground, 14 AWG under 50 ft, 12 AWG over 50 ft, and a dedicated GFCI. That callout does not print an ampere number. Printed page 16 prints a 15-amp GFCI dedicated circuit for the mechanism at the panel, with 20 AMP in parentheses for hydraulic. The 20 AMP figure lives in that parenthesis.
A feeder of exactly 50 ft is not printed.
Option 1, Key Switch KOSA, is a different conduit: (3) 12 AWG minimum identified wires plus one ground. Option 2, CoverLink wired control, is (4) 18 AWG minimum identified wires. The boxed note says all switches and control pads must be mounted in full view of the cover operation.
The electric key-switch motor, the 120 VAC diagram, and the bond marks are the subject of the automatic pool cover electrical requirements.
The warning on printed page 5 says these are minimum recommendations, that local and federal codes of standard safe practice apply, and that the prewiring instructions hold further mounting options. Those prewiring pages are not in this file. No extra wire size is added from a document the file only names.
Rule of thumb for the two splits
Rule of thumb. If the hose run is over 80 ft, the printed callout is two 1/2 in. hoses inside the 3 in. pipe, with sweeping bends and no sharp bend. If the pump feeder is over 50 ft, the pump junction-box callout is 12 AWG. A hydraulic motor that finishes below ground misses the above-ground sentence on printed pages 5 and 6.
The formula uses only those two printed splits.
Hose callout = two 1/2 in. hoses when L > 80 ft.
Wire gauge = 14 AWG when L < 50 ft; 12 AWG when L > 50 ft.
Equal to 80 ft, and equal to 50 ft, are not printed.
Worked example for a 62 ft feeder and a 90 ft hose run
Worked example. The lengths 62 ft and 90 ft are arithmetic assumptions. File 800024 does not print them as a sample pool or a sample run.
Pump feeder, assume 62 ft. Arithmetic: 62 - 50 = 12, so the run is 12 ft over the split. The over-50 callout applies: 12 AWG, 2 identified wires and 1 ground, on the dedicated GFCI. The ampere number on that drawing stays blank. The 20 AMP parenthesis on printed page 16 is a separate line.
Hose run, assume 90 ft. Arithmetic: 90 - 80 = 10, so the run is 10 ft over 80. The hose callout applies: two 1/2 in. hoses, in the 3 in. poly or PVC pipe, with sweeping bends.
A hose run of 70 ft, and a feeder of exactly 50 ft, stay blank.
What fails when a printed line is skipped
| Provision | Printed line | Dominant failure mode | Prevention on the sheet |
|---|---|---|---|
| Hose pipe | 3 in. poly or PVC, large sweeping bends, NO SHARP BENDS | A sharp bend in the pipe that carries the hose pair | Keep the sweeping bends in that 3 in. pipe |
| Motor height | Hydraulic motors must be mounted above ground level | A motor finished below grade, where pit water can reach it | Mount the motor above ground |
| Pump circuit | Dedicated GFCI on page 5, ampere blank. Page 16 parenthesis: 20 AMP for hydraulic | The pump landed on the 15-amp mechanism circuit | Use the 20 AMP parenthesis and the dedicated GFCI |
| Control view | Switches and control pads in full view of the cover | A switch where the operator cannot see the cover travel | Mount the switch or pad in full view |
| Hydramatic cap, printed page 9 | The filler cap stays on. Dirt and moisture affect pump and motor life | An open reservoir | Leave the filler cap on |
| Hydramatic pit, printed page 15 | Water should not stand in the pit. The system should not be submerged | The unit sitting in pit water | Keep standing water out of the pit |
Takeaway: a note that says hydraulic, and omits the above-ground motor, the 3 in. sweeping pipe, and the over-80 ft hose callout, is not the printed page 5 layout.
What the Hydramatic manual adds
Aquamatic Cover Systems, Hydramatic operational manual, cover dated 2007 Revision, is a different pack from file 800024. Printed page 9 says the pressure the powerpack supplies and the torque the motors produce move together: less pressure, less torque, and more pressure, more torque. That page uses the pressure as the sensor that stops the cover at the end of travel or at an obstruction. It describes an adjustable relief valve and does not print a PSI number. The 2000 PSI line stays on Cover-Pools printed page 14.
The same Hydramatic page says dirt and moisture affect the life of the pump and the hydraulic motors, and that the usual way in is the reservoir filler cap, which stays on. It recommends a fluid change at least every ten years. The replacement fluid is automatic transmission fluid, Dexron type only. The quantity printed there is approximately 3.5 quarts. The reservoir is filled to within 1 to 2 inches of the top, so the fluid has room to expand. That fill line is separate from the level check. Printed page 4, bi-annual item 3, says the ideal fluid level is 2 inches below the cap.
Printed page 15 says water should not be left standing in the pit, because the system should not be submerged. The drain path for a recessed housing is the pool cover drainage requirements. A cover that still will not travel after that pit is dry is a separate check on automatic pool cover motor problems. The same Hydramatic page says the cover is designed to float and functions properly when the water stays within 1 to 2 inches of normal operating level. Decisions past that sentence belong on pool water level with an automatic cover. The page also says not to run the cover below 40 F, printed as 40*F, because that produces cold cracks in the vinyl.
The same page states that a cubic foot of water weighs approximately 62 lb, and that 1 inch of water on a 20 ft by 40 ft cover equals about two tons, or about 4,000 lb. It then says the net effect is essentially negligible when pool water completely supports the cover.
Worked example, arithmetic only, from those printed inputs. The manual does not print the fraction below.
20 × 40 × (1/12) × 62 = 12,400/3 lb, which is 4,133 lb to the nearest pound. The manual states about 4,000 lb. The gap between that product and the manual's round figure is 4,133 - 4,000 = 133 lb, again arithmetic.
Printed page 16 of the Hydramatic manual says damage to the cover, the tracks, and the coping can occur if the cover has less than 85 percent contact with the water surface. If contact is under 85 percent, that sentence is the one that applies.
File 800024 printed page 16 lists cost rows and prints no prices. The hydraulic rows are the 3 in. conduit for the hydraulic-unit housing, the 20 AMP circuit, and a hydraulic pump with hydraulic hoses. A sharp bend buried in that pipe is a second opening of the same conduit row. The Hydramatic fluid interval is at least ten years, at about 3.5 quarts. Neither document prints a dollar figure.
A site with no dry place above grade for the motor and the pump is the comparison on hydraulic versus electric pool covers.
When these sheets do not apply
The electric 3/4 hp key-switch diagram is a different arrangement from the hose callout. A hose size for a run of 80 ft or less is absent from printed page 5. The 2000 PSI line is not a Hydramatic setpoint. Dexron and 3.5 quarts are not a Cover-Pools reservoir fill. The prewiring instructions are named and are not in the pages read here. The cover of file 800024 assigns installation and service to a contractor licensed and qualified in pool equipment where the jurisdiction requires that license.
Frequently asked questions
Does printed page 5 give a hose size at 80 ft or under?
No. The callout reads two 1/2 in. hoses over 80 ft. The equal case and every shorter run are blank on that page.
Is 20 AMP printed on the hydraulic diagram?
No. Printed page 5 shows a dedicated GFCI and leaves the ampere number off that callout. Printed page 16 puts 20 AMP in parentheses for hydraulic, after the 15-amp mechanism circuit.
Does the Hydramatic manual print 2000 PSI?
No. Printed page 9 describes an adjustable relief valve and does not print a PSI number. The 1 1/2 hp/2000 PSI line is Cover-Pools file 800024, printed page 14.
Method and sources
Updated October 2026. The figures above are the lines printed on the cited pages. A length used in a worked example is marked as arithmetic. A cell the sheet leaves off stays blank. A local library search for hydraulic pool cover returned trade notes on hydraulic fluid, pool shows, and other equipment. None was a pool-cover installation sheet, so none supplies a figure here. A cached search list for the same phrase returned no stored result rows. No new search data was purchased.
- Cover-Pools, General Information for Installing an Automatic Pool Cover, file 800024 Rel-0024, fetched 2026-10-18. Printed page 5: optional hydraulic power system, motor at the housing end, pump unit remote, 050275 or 050276, two 1/2 in. hoses over 80 ft, 3 in. conduit, 3 in. poly or PVC, large sweeping bends, no sharp bends, motors above ground, dedicated GFCI, 14 AWG under 50 ft, 12 AWG over 50 ft, KOSA at 12 AWG minimum plus one ground, CoverLink at 18 AWG minimum, switches in full view. Printed page 6: Hydraulic 1-1/2 hp motor label, above-ground note repeated. Printed page 14: 1 1/2 hp/2000 PSI hydraulic system. Printed page 16: 3 in. conduit for hydraulic-unit housing, 20 AMP for hydraulic, hydraulic pump with hydraulic hoses. Cover: installation and service by a licensed pool-equipment contractor where the jurisdiction requires that license.
- Aquamatic Cover Systems, Hydramatic operational manual, cover page 2007 Revision. The file used is the copy saved from aquamatic.com on 2026-10-11. The exact PDF path was not retained with that download. A guessed path returned 404 on 2026-10-18 and was not fetched again. Printed page 4: ideal fluid level 2 in. below the cap. Printed page 9: pressure and torque move together, adjustable relief valve, no PSI number, filler cap on, fluid change at least every ten years, Dexron type only, approximately 3.5 quarts, fill to within 1 to 2 in. of the top. Printed page 15: do not leave the system submerged, water level within 1 to 2 in. of normal, do not run the cover below 40 F, cubic foot approximately 62 lb, 1 in. of water on a 20 ft by 40 ft cover about 4,000 lb. Printed page 16: less than 85 percent contact with the water surface.
Related guides
- Hydraulic automatic pool covers: the parent page for the drive choice, before the hose path.
- Automatic pool cover electrical requirements: the electric motor diagram, the bond, and the same 50 ft split on that sheet.
- Pool cover box and housing: lid, roller, and box, which stay on the drawing when the pump is remote.
- Pool cover drainage requirements: how water is supposed to leave a recessed housing.
- Hydraulic versus electric pool covers: the comparison when the site has no dry place above grade for the pump.