Automatic Pool Cover Electrical Requirements

A motor left under water, or a supply that is not the dedicated GFCI on the sheet, damages the drive and leaves the cover stuck. Automatic pool cover electrical requirements are the supply, the 50 ft wire split, the switch view, and the bond printed on the Cover-Pools sheets.

Automatic pool cover electrical requirements, on Cover-Pools file 800024 Rel-0024 printed page 5, are a 120 VAC 15 AMP dedicated GFCI for the 3/4 hp electric key-switch motor, 14 AWG under 50 ft, 12 AWG over 50 ft, and a switch in full view of the cover. Printed page 16 lists a 15-amp dedicated GFCI at the panel, 20 AMP for hydraulic, and a 110 V motor. Page 5 prints 120 VAC. The hydraulic diagram keeps a dedicated GFCI at the pump and the motor above ground. Printed page 6 adds a No. 8 bond at both ends and places the auto-shutoff away from the housing. File 601985 adds two 8 AWG bonds with 4 ft minimum inside the box. These are minimum recommendations, and the drawings send the conduit and the bond to a certified electrician.

Infographic titled Automatic Pool Cover Electrical Requirements, with the subtitle Dedicated circuit, full view, and bond, icons labeled 15 A GFCI, 50 ft split, Full view, and No. 8 bond, and a housing with a motor and a dedicated GFCI.
The banner names the four checks on this page: the dedicated GFCI, the 50 ft wire split, a switch in full view, and the No. 8 bond. The housing on the right is an example. It carries no brand nameplate.
Input or item Typical value or source Why it matters
Electric key-switch supply, file 800024 printed page 5 120 VAC 15 AMP dedicated G.F.C.I. Hot, neutral, ground. 3/4 hp motor with slip clutch This is the standard electric diagram
Wire split on that diagram, and again on printed page 6 14 AWG under 50 ft. 12 AWG over 50 ft Both sides are printed. The equal case is not
Wire size at exactly 50 ft The sheet prints under and over, and leaves the equal case off the page
Motor whip, printed page 5 36 in waterproof flex, 1/2 in NPT watertight connector, 14 AWG minimum, wire extended 8 in past the end The whip length is printed. A conduit-fill number is not
Checklist, printed page 16 15-amp GFCI dedicated circuit at the panel (20 AMP for hydraulic). Runs over 50 ft require heavy-gauge wire. 110 V motor and hard-wired 3-wire key 20 AMP and 110 V live on this list. They are not repeated as those words on the page 5 hydraulic diagram
Hydraulic pump conduit, printed page 5 Dedicated GFCI. 2 identified wires and 1 ground. 14 AWG under 50 ft and 12 AWG over 50 ft. Motor above ground The amp number on this drawing is blank
KOSA key, printed page 5 (3) 12 AWG minimum identified wires plus one ground This option is 12 AWG minimum, not the 14/12 split
CoverLink wired control, printed page 5 (4) 18 AWG minimum identified wires The control run is a smaller gauge than the pump supply
Auto-shutoff bond, printed page 6 #8 bonding wire at both ends. Auto-shutoff away from the housing The bond is marked on the housing, and the control sits at the equipment room or pad
T4 Versa bond, file 601985 Rel-0002 2 solid 8 AWG wires, motor end and opposite end, minimum 4 ft inside the box. No. 8 AWG or larger. Canada: No. 6 AWG or larger The sheet is provisional. Its pool table stops at 20 ft wide by 50 ft long
Housing sleeve, file 800024 printed pages 7 and 10 Conduit on the motor end, no more than 4 in into the box, 6 in maximum from the top The 4 in figure is the sleeve projection, kept separate from any drain centerline on the same drawings

Four points sit on those lines:

  • The electric diagram and the checklist do not print the same voltage words. Keep 120 VAC with page 5 and 110 V with page 16.
  • A run under 50 ft and a run over 50 ft take different AWG lines. A run of exactly 50 ft has no printed AWG.
  • The hydraulic diagram's dedicated GFCI has no amp number. The 20 AMP figure is only the checklist parenthetical.
  • The bond is a No. 8 at both ends on these sheets. Canada No. 6 AWG is only the T4 Versa bonding paragraph.

This page sits under the installation sequence for an automatic cover. The circuit is a construction line on that sequence, read with the new construction guide before the deck closes.

The standard electric key switch

File 800024 Rel-0024, printed page 5, titles the standard arrangement as an electric motor with key switch and prints a 3/4 hp motor with slip clutch. The supply callout reads conduit to a 120 VAC 15 AMP dedicated G.F.C.I., with hot, neutral, and ground. The same callout prints 14 AWG under 50 ft, 12 AWG over 50 ft, and a dedicated GFCI. A second conduit is three different colored wires and one ground, labeled neutral, Dir 1, Dir 2, and ground, and that run prints the same under-50 and over-50 split. The whip at the motor is 36 inches of waterproof flex conduit with a 1/2 inch NPT watertight connector, 14 AWG minimum, with the wire extended 8 inches past the conduit end. The boxed note says all switches must be mounted in full view of the cover operation.

The warning on that page says these are minimum recommendations only, that local and federal codes of standard safe practice must be followed, and that the prewiring instructions hold the detailed mounting options. Those prewiring pages are not in this file. This page does not add figures from a document it does not contain.

Printed page 16 is the cost checklist, and it is a separate list from the diagram. It prints a 15-amp GFCI dedicated circuit for the mechanism at the panel, with 20 AMP in parentheses for hydraulic. It prints that electric runs over 50 ft require heavy-gauge wire. It prints 1/2 inch conduit for mechanism power, an electric run to the key switch, and 1/2 inch conduit for the low-voltage wires required with auto-shutoff or CoverLink wired controls. Under power and controls it prints a 110 V motor and a hard-wired 3-wire key as standard. The diagram's 120 VAC and the checklist's 110 V are both printed in file 800024. The file does not print a line that one of those voltages replaces the other.

Who pulls that circuit is a row on the construction coordination guide.

The hydraulic feed stops at the pump

The optional hydraulic diagram on printed page 5 puts the dedicated GFCI on the conduit to the hydraulic pump junction box: 2 identified wires and 1 ground, 14 AWG under 50 ft, and 12 AWG over 50 ft. That callout does not print 15 AMP or 20 AMP. The 20 AMP figure stays on the printed page 16 checklist. Option 1, the KOSA key switch, is a conduit with (3) 12 AWG minimum identified wires plus one ground. Option 2, CoverLink wired control, is a conduit with (4) 18 AWG minimum identified wires. The pump units drawn there are labeled 050275 or 050276. The note says hydraulic motors must be mounted above ground level. Switches and control pads must be mounted in full view of the cover operation.

The hose path on that drawing is a different line from the electrical conduit. It prints two 1/2 inch hoses over 80 ft, and a 3 inch poly or PVC pipe from the housing to the power unit, with large sweeping bends and no sharp bends. The hose route continues on the hydraulic system design guide. Which drive to provision is the hydraulic and electric comparison.

Diagram of two feeds: an electric housing motor on a 120 VAC 15 AMP dedicated GFCI, and a hydraulic pump with a dedicated GFCI above ground.
Electric and hydraulic feeds as file 800024 printed page 5 separates them. The 20 AMP hydraulic figure is on the checklist, so this diagram leaves the pump amp blank. No brand nameplate.

Auto-shutoff, the 5 V key, and the bond

Printed page 6 is the auto-shutoff with an accessory board or AquaLink, for a 3/4 hp motor or a hydraulic motor. Option 1 mounts the auto-shutoff outside the housing. The low-voltage key is labeled Key Switch 5v, with a conduit of (3) 18 AWG identified wires. That 5 V run is a different circuit from the 120 VAC motor supply on printed page 5. The low-voltage controls and motor-power checklist keeps those two documents apart. CoverLink wired control on that option is (4) 18 AWG minimum. Another conduit is (4) 14 AWG wires for power and (3) 18 AWG for sensors. Main power is a dedicated GFCI, 14 AWG under 50 ft, 12 AWG over 50 ft, and a conduit for main power with (3) 14 AWG identified wires: hot, neutral, and ground. The whip is 36 inches of waterproof flex with a 1/2 inch NPT watertight connector, and the sheet says to extend (4) 14 AWG wires 8 inches past the conduit end. The drawing labels the hydraulic unit 1-1/2 hp and the electric motor 3/4 hp, and it repeats that hydraulic motors must be mounted above ground level. A #8 bonding wire is marked at both ends of the housing. The sheet says to install the auto-shutoff away from the cover housing, in or by the equipment room or equipment pad.

The wireless block on the same page prints a clear line of reception and says all control pads must be mounted in full view of the cover operation, with the accessory board away from the housing. Main power repeats the dedicated GFCI, the 14/12 split, and (3) 14 AWG identified wires. The whip is 36 inches of flex with a 1/2 inch NPT watertight connector for 14 AWG, extended 8 inches past the end. That wireless whip note does not print a conductor count of (4). The #8 bonding wire is marked on both sides.

Housing with a No. 8 bond at each end, and an auto-shutoff box set away from the housing at the equipment room or pad.
Bond locations from file 800024 printed page 6, which marks #8 at both ends and places the auto-shutoff away from the housing. The 4 ft inside-box length is the separate T4 Versa note. No brand nameplate.

File 601985 Rel-0002, the T4 Versa recessed box sheet, is marked provisional. Its bond line prints 2 solid bond wires, 8 AWG, one at the motor end and one at the opposite end, from the pool bond grid with a minimum of 4 ft inside the box. The bonding paragraph says the equipment must be bonded in accordance with the National Electrical Code, or in Canada the Canadian Electrical Code, with a solid copper conductor, No. 8 AWG or larger, and in Canada No. 6 AWG or larger. The sheet says to consult a certified electrician and the pre-wiring diagrams. Its conduit note says to run the conduit from the center of the box on flex conduit with a 1/2 inch seal-tight connector. The dimension table is for pools up to 20 ft wide by 50 ft long. That 50 ft is a pool length. It is a different measurement from the 50 ft conductor split on file 800024.

The same provisional sheet has a row for an auto-shutoff located in the box. That row prints a motor-end length of 17 inches minimum, against 14 inches minimum on the motor-below row. File 800024 printed page 6 says to install the auto-shutoff away from the housing. The two sheets print different locations. Use the sheet that names the mechanism on the job, and leave the other location off that drawing.

Where the sleeve enters the housing

On file 800024 the recessed-box drawings put the electrical sleeve on the motor end. Printed pages 7 and 10 say the conduit must be on the motor end, must not protrude more than 4 inches into the box, and sits 6 inches maximum from the top of the box. Printed pages 8 and 9 keep the limit of no more than 4 inches into the box on the Autosave recessed box. Each of those drawings says to consult a certified electrician and the pre-wiring diagrams for conduit and bonding. The 4 inch projection is the sleeve. A drain centerline printed on the same sheets is a different 4 inch measurement, covered on the box and housing guide.

Rule of thumb for the 50 ft split

Rule of thumb. If the conductor run is under 50 ft, the electric and auto-shutoff diagrams print 14 AWG. If the conductor run is over 50 ft, those diagrams print 12 AWG, and the printed page 16 checklist calls the run heavy-gauge wire. If a hydraulic motor would finish at or below ground, it misses the above-ground note on printed pages 5 and 6. If a switch or control pad cannot see the cover travel, it misses the full-view note on those pages.

The formula uses only that printed split.

Wire side = 14 AWG when length < 50 ft; 12 AWG when length > 50 ft.

The sheet does not print a wire size at length = 50 ft. That cell stays blank.

Worked example. The three lengths below are arithmetic assumptions. File 800024 does not print them as a sample pool or a sample run.

  • Assume 40 ft. 40 is less than 50, so the under-50 line applies. That line prints 14 AWG.
  • Assume 60 ft. 60 is greater than 50, so the over-50 line applies. That line prints 12 AWG.
  • Assume 50 ft. The sheet prints under 50 ft and over 50 ft and does not print the equal case. The wire size stays blank.
Number line with 14 AWG under 50 ft, 12 AWG over 50 ft, and a blank mark at exactly 50 ft.
The 50 ft mark is the split printed on the electric and auto-shutoff diagrams. The equal case has no AWG on the sheet. The 40 ft and 60 ft checks in the text are arithmetic, not lengths the sheet prints.

A pull made with 14 AWG, then found to be over 50 ft, is a second pull onto the over-50 side. The checklist already flags runs over 50 ft before that pull. The file prints no dollar figure for the return trip. Landing the dedicated circuit while the housing is open is the point of the installation sequence.

What fails when a printed line is skipped

Arrangement the sheet prints Dominant failure mode and prevention
14 AWG on a run over 50 ft The over-50 line prints 12 AWG, and the checklist calls that run heavy-gauge. Pull the over-50 side before the deck closes
Supply other than the dedicated GFCI Printed page 5 names a 120 VAC 15 AMP dedicated GFCI for the electric key switch. The checklist names a 15-amp dedicated GFCI at the panel, and 20 AMP for hydraulic. Land the dedicated circuit that line names
Switch or pad outside the view of the cover The boxed note on pages 5 and 6 requires full view of the cover operation. Place the control where it sees the travel
Hydraulic motor at or below ground Pages 5 and 6 say hydraulic motors must be mounted above ground level. Set the pack above ground
Sharp bend in the 3 inch hose pipe Page 5 prints large sweeping bends and no sharp bends on the pipe from housing to power unit. Keep that pipe on the hydraulic system design guide
Auto-shutoff left in the housing on an 800024 page 6 job That page says to install it away from the housing. The T4 Versa row that locates an auto-shutoff in the box is the other sheet
#8 missing at one end Page 6 marks the #8 bond at both ends. File 601985 prints two 8 AWG wires, one at each end
Motor left submersed T3 Evo owner's manual, file 800249 Rev A, printed page 9, says not to leave the motor submersed longer than a few hours. Keep the housing drain clear on the housing drainage requirements

Takeaway: copy the supply, the AWG side, the view, and the bond from the sheet that names the mechanism.

What an owner can check before anyone opens a box

Printed page 9 of the T3 Evo owner's manual, section 6.1, says the motor is waterproof and capable of short-term submersion, and that the motor should not stay submersed for longer than a few hours. A below-deck or recessed housing needs drainage, and the drains stay clear. The same section says the motor has an internal thermal overload that resets on its own when the motor cools. That overload is not the dedicated GFCI on the installation diagrams. Section 6.4 says to turn off all electricity to the cover before rinsing the mechanism. The motor will take a direct spray at low force. The page prints no spray pressure.

Standing water in the housing is a stop before another run. The drain path is the housing drainage requirements. A drive that still will not travel after the housing is dry belongs on the motor problem checks.

Printed page 13 says to turn the power to the cover off at the mains circuit breaker before adjustment or other maintenance, so the cover is not running while someone is at the mechanism. The troubleshooting table on printed page 19 says that if the control-pad LEDs do not light, check that the circuit breaker is on. If that breaker is on and the LEDs still do not light, the manual sends the job to the local cover dealer.

The front of file 800024 says the product must be installed and serviced by a contractor licensed and qualified in pool equipment where the jurisdiction requires that license. The housing drawings say to consult a certified electrician for conduit and bonding. This page records the printed provisions.

Where these sheets stop

File 800024 says the diagrams are general information and that the installation instructions govern the details. The electrical warning says the figures are minimum recommendations and that local and federal codes still apply. The prewiring instructions are named and are not in the pages read here, so none of their extra wire sizes are added. File 601985 is provisional, and its dimension table stops at 20 ft wide by 50 ft long. A longer pool is outside that table. The Canada No. 6 AWG figure is in the T4 bonding paragraph. File 800024 printed page 6 prints #8 and does not print the Canada size. The hydraulic diagrams do not print 20 AMP. That number is only the checklist parenthetical. A disconnect distance, a wire size at exactly 50 ft, and a price are not printed. Those cells stay blank.

Common questions

Does file 800024 print how far a disconnect sits from the motor?

No. Printed pages 5 and 6 require the switch or control pad to be in full view of the cover operation. They print a dedicated GFCI and, on page 6, a #8 bond at both ends. They do not print a distance from the motor to a disconnect.

Does the motor thermal overload replace the dedicated GFCI?

No. Section 6.1 of the T3 Evo manual describes an internal overload that resets when the motor cools. The dedicated GFCI is the supply on file 800024 printed pages 5, 6, and 16. The two devices are printed on different pages, and neither page says one stands in for the other.

Sources and method

Updated October 2026. This page records automatic pool cover electrical requirements from public Cover-Pools sheets fetched on 18 October 2026. It is an independent account of those sheets. The housing drawings send conduit and bonding to a certified electrician and the prewiring diagrams.

  • Cover-Pools, General Information for Installing an Automatic Pool Cover, file 800024 Rel-0024. Printed page 5: 3/4 hp electric motor with key switch, 120 VAC 15 AMP dedicated G.F.C.I., 14 AWG under 50 ft, 12 AWG over 50 ft, full view of the cover, 36 in flex whip, 14 AWG minimum, 8 in past the end. Hydraulic: dedicated GFCI, 14/12 split, KOSA at 12 AWG minimum plus a ground, CoverLink at 18 AWG minimum, motors above ground, hoses and the 3 in sweeping pipe. Printed page 6: 5 V key at 18 AWG, #8 bond both ends, auto-shutoff away from the housing, 1-1/2 hp hydraulic and 3/4 hp electric labels, wireless full view and clear line of reception. Printed pages 7 and 10: motor-end conduit, 4 in maximum into the box, 6 in maximum from the top. Printed pages 8 and 9: 4 in maximum into the box. Printed page 16: 15-amp dedicated GFCI, 20 AMP for hydraulic, heavy-gauge wire over 50 ft, 110 V motor.
  • Cover-Pools, T4 Versa Recessed Box Details, file 601985 Rel-0002, copyright 2020, marked provisional. Two solid 8 AWG bond wires, minimum 4 ft inside the box. Bonding paragraph: National Electrical Code or Canadian Electrical Code, No. 8 AWG or larger, Canada No. 6 AWG or larger. Certified electrician. Flex conduit from the center with a 1/2 in seal-tight connector. Dimension table up to 20 ft wide by 50 ft long. Auto-shutoff-in-box row: 17 in minimum at the motor end.
  • Cover-Pools, T3 Evo Owner's Manual, file 800249 Rev A. Printed page 9: short-term submersion, not longer than a few hours, drainage kept clear, thermal overload resets when cool, electricity off before a mechanism rinse. Printed page 13: power off at the mains circuit breaker before maintenance. Printed page 19: if control-pad LEDs stay dark with the breaker on, contact the local cover dealer.

A local library search for pool cover electrical and GFCI returned trade notes on outdoor GFCI devices and tester products. None was a pool-cover installation sheet, so none is used as a figure source. A cached search-data list for pool cover returned no stored SERP rows. No new SERP was purchased.