Pool Cover Project Specification Checklist

Leaving the housing end, the coping seat, and the power choice off the drawings is rework after the beam is shot. A pool cover project specification checklist, on Cover-Pools file 800024 Rel-0024, is the sheet list that file prints: track, a 3 in housing drain, electric or hydraulic power, the mechanism box, coping, the lid, and the specifications review on printed page 14. Square-foot pricing comes after those lines are filled, and a cell the sheet does not print stays blank.

Infographic titled Pool Cover Project Specification Checklist, subtitle File 800024, with icons Plan, Box, Coping, and Power, beside a pool rectangle labeled Housing and Tracks. No brand nameplate.
Schematic, not to scale.

Lines the specification has to name

A pool cover project specification checklist is the set of lines Cover-Pools file 800024 Rel-0024 prints before the square-foot line is filled. The file is the 2015 installation overview for a Save-T 3 cover system or an Autosave spa cover. Pool builders copy track, the housing, the drain, the power choice, the coping, and the lid onto the drawings. Printed page 14 reviews the Save-T fabric, tracks, mechanism, housing, power, and safety lines. Printed page 16 lists the scope beside the square-foot line and prints no dollar amount. Construction coordination is the order those lines have to be true before the next pour. The parts hub is the photograph list for the mechanism names on printed page 14.

Minimum sheet set for a coverable pool

The minimum sheet set for a coverable pool is a plan with the housing end marked, a section through the box, a coping detail, and a power note. Printed page 14 is the specifications review those four drawings carry. The figure names the four sheets and does not mix a Save-T row with an Autosave row.

The plan uses printed page 3. The tracks, and rectangular pools, must be a true rectangle, and the tracks must be perpendicular to the mechanism and the recessed housing at 90 degrees. The motor can be on either end. Over-dig the recessed cover-box end 18 in beyond the forms. Do not install plumbing within 14 in of the deck in the housing area. Do not locate skimmers in the lowered pool wall. All corners must be square, with no radius, on the finished tile line or the coping. Place a 3 in drain in the floor or the wall of the recessed housing. The diagram labels 36 in of excavation from the waterline on the motor side and 16 in on the opposite side. The 6 ft, 8 ft, and 10 ft corner, and track space AB = CD, stay on how to measure a pool for an automatic cover. Drain to air or drain to a pit is the destination line on printed page 16, and the rest of that path is on drainage requirements.

Printed page 4 adds two track sentences. A flush track must be set back 6 in from the pool edge. A universal track may be mounted at the pool edge. Do not locate the track on top of a skimmer lid. There is also a 1 ft minimum setback and a mark 2 ft beyond the pool on that drawing.

Rule of thumb. If the finished surface is under 2 in thick, or the material is softer, printed page 1 does not treat that surface as basic undertrack mounting. Inverted mount is the listed path for flagstone, slate, or tile in that case. Deck straps are mounted every 2 ft of track for porous coping, brick, flagstone, and materials under 2 in thick. Write that choice on pool cover coping integration before the coping is poured.

The coping detail uses printed pages 11 and 12. At the recessed box end, the bond beam must be shot 2-1/2 in lower than the side walls, 2 in finished with tile. Any interior wall, such as a spa, is shot lower by that same pair. Coping corners are square. The minimum cantilever from the tile is 2 in on the side walls and 3 in on the end wall opposite the mechanism. The opening for the track is 2-1/2 in at the box, 2 in finished with tile, sloping to 3 in inside the pool. The coping note prints a box minimum of 12-1/2 in wide by 12-1/2 in deep. Those numerals are the under-55 depth and width. The sheet does not print a sentence that fills the over-55 row, or the length equal to 55 ft, from this note. The track must be mounted on the flat bottom of the coping. Printed page 12 states that the coping measurement is not the track space, and that the coping must not extend more than 1/2 in past the edge of the track. The lowered wall uses a 1/4 in round edge if that edge is exposed.

The power note uses printed pages 5 and 14. Page 5 labels a 3/4 hp motor with slip clutch as standard equipment, on a 120 VAC 15 AMP dedicated G.F.C.I., with the key switch at 120V. The key-switch diagram prints 14 AWG under 50 ft and 12 AWG over 50 ft. A run equal to 50 ft stays blank. Printed page 16 says electric runs over 50 ft require heavy-gauge wire and does not print a gauge on that line. The same under-and-over split is on the conduit to the hydraulic pump junction box. The hydraulic key-switch conduit on that page is 12 AWG minimum, which is a separate line from the 14 AWG under-50 print. Switches must be mounted in full view of the cover operation. The motor whip is 36 in of waterproof flex conduit, 1/2 in NPT, 14 AWG minimum, with the wire extended 8 in past the conduit end. Hydraulic motors must be mounted above ground level. The hose path is 3 in conduit, or 3 in poly or PVC, with sweeping bends and no sharp bends, and two 1/2 in hoses over 80 ft. A hose note equal to 80 ft stays blank. Electrical requirements hold the circuit. Hydraulic system design holds the pump height and the hose path.

Printed page 14 names a 3/4 hp waterproof electric motor and an optional Ultimate high-torque motor, and it prints no torque. The Save-T 3 Big Red panel at the end of the same file prints 1600 in-lbs at 41 rpm for the 3/4 hp motor, and 1375 in-lbs at 27 rpm for the optional 3/4 hp high-torque motor. The hydraulic line on printed page 14 is 1-1/2 hp at 2000 PSI. The standard electric system comes with either the slip clutch or the auto-shutoff. The spec names which one. Printed page 14 also says bonding is included with all automatic systems, and that an automatic water-removal cover pump is included. The note says a solid safety cover without a pump is not approved to ASTM F1346-91, and that an automatic cover installed without bonding is not a UL-listed product. Printed page 16 labels the motor 110 V and the panel circuit 15-amp GFCI, with 20 AMP for hydraulic. The file prints 120V on page 5 and 110 V on page 16 and does not equate the two labels.

Input or itemTypical value or sourceWhy it matters
File800024 Rel-0024, copyright 2015, Cover-PoolsThe installation overview this checklist copies
Track styles, printed page 14Underside, SnapTop, Universal, Slim, or Flush. Extrusions are 100 percent anodizedThe coping and the box follow this name
Fabric, printed page 14PVC vinyl over reinforced polyester mesh. 18 oz per square yard. 28 mil laminated vinylWeight and thickness on the review
Strength, printed page 14Exceeds the ASTM F1346-91 minimum of 485 lbs per 4 ft radiusThe strength line. Torque is not this line
Rope, printed page 14Low-stretch rope, 70,000+ cyclic loading fatigue life. Optional Ultimate rope, 100,000+, or stainless steel cableThe spec names which rope
Standard colors, printed page 14Dusky blue, royal blue, light blue, aqua, forest green, beige, tan, brown, gray, slate gray, and blackEleven names. Special-order colors have no lead time on the page
Electric motor, printed page 143/4 hp waterproof. No torque on this pageThe Big Red panel is the torque line
Torque, Big Red panel1600 in-lbs at 41 rpm. Optional high-torque motor, 1375 in-lbs at 27 rpm, still 3/4 hpPrinted page 14 does not print these figures
Hydraulic system, printed page 141-1/2 hp at 2000 PSIThe other power line on the review
Key-switch wire, printed page 514 AWG under 50 ft. 12 AWG over 50 ftA run equal to 50 ft stays blank
Equal to 50 ftThe wire sentences say under and over
Square feet, printed page 15Track space times pool length. No dollar amountPricing comes after the sheets exist
Standard box equal to 55 ftPrinted page 7 has under 55 and over 55
Four sheets from file 800024: Plan with the housing end marked and the motor on either end, Box section for one box family, Save-T or Autosave, Coping detail with cantilever and opening and the track on the flat bottom, and Power note for electric or hydraulic.
Schematic, not to scale.

Save-T rows stay off the Autosave rows

A standard Save-T 3 box length equal to 55 ft stays blank on printed page 7. On that underside drawing the conduit must be on the motor end, must not protrude more than 4 in into the box, and must be 6 in maximum from the top of the box. The drain centerline is 4 in maximum from the end wall, and the drain can be on either end. The side view prints a minimum 2 in clearance for tracks. The note says to consult a certified electrician and the prewiring diagrams for conduit and bonding. The under-55 row and the over-55 row are the two standard rows. The UPB row is a different box, and that row does say up to 55 ft. Pool cover boxes and housings is the housing page. The rows below are only the cells file 800024 prints.

Rule of thumb for the box. If the Save-T 3 underside row says under 55 ft long on the 24 ft width label, depth and width are 12-1/2 in minimum. If that row says over 55 ft long, depth and width are 14-1/2 in, and the word minimum is not printed on those two cells. The equal length stays blank.

Printed page 10 reprints the Save-T 3 cells for a deck-mount box on universal track or on SnapTop. It reprints motor, opposite, beam, throat, depth, and width. It does not reprint the Autosave cells. The wood-box prose on that page calls for 2 in by 12 in pressure-treated lumber or redwood, and upper trim of 2 in by 4 in pressure-treated lumber or redwood. The Everlast bench kit prints 16-1/4 in to 17-1/2 in and 4 colors. The bench frame prints a maximum height of 20 in by 24 in wide, and surface material is not included. Fiberglass ends are printed as available in white. The Big Red panel prints a roller tube of 17 gauge aluminum in 6 in and 8 in diameters.

Printed pages 8 and 9 are the Autosave tables, for pools up to 13 ft or 200 square feet. Option 1 brings the conduit from the back, from the center of the housing, with flex conduit and a 1/2 in watertight connector. Option 2 brings the conduit from the side, as close to the rear wall as possible, and not more than 4 in into the box. Both pages print the dimension cells below. The conduit note is what changes. A pool over 13 ft, or over 200 square feet, has no Autosave row. The side views label 8-1/2 in and 12 in on the motor conduit. Those labels are not the depth column and not the width column.

Printed page 14 names the lid on the review: a standard 12 in aluminum lid with a 4 in or a 6 in hinge, Bezel lids 16 in and 18 in wide, and Vanishing Lid trays 12 in to 24 in wide. Lid options carries the bracket spacing. Printed page 13 says a walk-on Vanishing Lid needs a concrete housing, or a wood housing with a concrete wall poured behind the box. The maximum tray is 24 in wide and 24 in long. The same note says the deck must be thicker for an extended tray if the leading edge fits under the tray, and it prints no thickness.

Input or itemTypical value or sourceWhy it matters
Save-T 3 underside, under 55 ft long x 24 ft wide, printed page 7Motor 32 in. Opposite 10 in. Beam 8-12 in. Throat 2 in minimum to the finished beam. Depth 12-1/2 in minimum. Width 12-1/2 in minimumThe word minimum is printed on throat, depth, and width
UPB box, up to 55 ft long, printed page 7Motor 32 in. Opposite 10 in. Beam 8-12 in. Throat 2 in minimum. Depth 13 in. Width 13 inDepth and width do not print the word minimum
Save-T 3 underside, over 55 ft long x 24 ft wide, printed page 7Motor 32 in. Opposite 10 in. Beam 8-12 in. Throat 2 in minimum. Depth 14-1/2 in. Width 14-1/2 inDepth and width do not print the word minimum
Standard Save-T 3 box, length equal to 55 ftUnder 55 and over 55 leave this cell out. The UPB row is the one that says up to 55 ft
Over 65 ft long, or over 25 ft wide, and vanishing-edge pools, printed page 7Call Cover-Pools at 1-800-447-2838. No box size is printedThe under-55 minimums do not fill this row
Length equal to 65 ft, or width equal to 25 ftThe call line says over
Autosave, up to 13 ft or 200 square feet, motor behind, printed pages 8 and 9Motor 9 in minimum. Opposite 9 in minimum. Beam 10 in minimum. Throat 1 in to the finished beam. Depth 9 in minimum. Width 12-1/2 in minimumBoth conduit options print this row
Autosave, motor behind with auto-shutoffMotor 14-1/2 in minimum. Opposite 9 in minimum. Beam 10 in minimum. Throat 1 in to the finished beam. Depth 9 in minimum. Width 12-1/2 in minimumThe motor cell is the one that changes
Autosave, motor belowMotor 12-1/2 in minimum. Opposite 9 in minimum. Beam 10 in minimum. Throat 1 in to the finished beam. Depth 9 in minimum. Width 12-1/2 in minimumBoth conduit options print this row
Autosave, motor below with auto-shutoffMotor 12-1/2 in minimum. Opposite 9 in minimum. Beam 10 in minimum. Throat 1 in to the finished beam. Depth 9 in minimum. Width 14-1/2 in minimumThe width cell is 14-1/2 in minimum on this row
Autosave over 13 ft, or over 200 square feetNo row is printed
Equal cases left blank on file 800024: 55 ft standard box, 50 ft wire run, 25 ft track width, 65 ft pool length, and Autosave over 13 ft. Each value cell says Blank.
Schematic, not to scale.

What fails when a line is left blank

Each miss below is a line the file already prints. The prevention is the line the specification has to name before the next pour.

Line left blankDominant failure modePrevention the sheet prints
Surface under 2 in poured as an underside seatPrinted page 1: under 2 in, or a softer material, is outside basic undertrack mountingName inverted mount, or deck straps every 2 ft of track
No housing drainWater stays in the recessed housingPlace a 3 in drain in the floor or the wall. Printed page 16: drain to air or drain to a pit
Plumbing in the housing bandThe pipe occupies the zone within 14 in of the deckKeep that band clear on the plan
Switch outside the view of the coverThe operator cannot see the cover moveMount switches in full view of the cover operation
Hydraulic motor below gradeThe motor sits below the height printed page 5 requiresMount hydraulic motors above ground level
Sharp bend in the hose pipeA sharp bend is outside the printed hose pathUse sweeping bends. The note says no sharp bends
Save-T depth written into an Autosave rowThe two tables are different coversKeep printed page 7 off printed pages 8 and 9
Standard box at 55 ft filled from the under-55 rowThe equal case is not printedVerify box dimensions with the manufacturer for exact 55 ft lengths
Solid safety cover with the pump omittedPrinted page 14: a solid safety cover without a pump is not approved to ASTM F1346-91The same note says the cover pump is included on this system
Walk-on tray without the concrete anchorThe brackets have nothing to anchor toPrinted page 13: concrete housing, or a concrete wall behind a wood box

Square feet on the pricing line

Cover square feet = track space x pool length. Printed page 15 states that product. The motor mechanism in the pricing note is one foot from the pool edge, and the motor position is left or right. Track widths over 25 ft, or lengths over 65 ft, require factory approval. The maximum track space on that sentence is 36 ft. A track width equal to 25 ft stays blank. A pool length equal to 65 ft stays blank.

Worked example. Printed page 15 does not print a sample pool. The two lengths below are arithmetic assumptions. Arithmetic: track space 22 ft and pool length 44 ft. Arithmetic: 22 x 44 = 968. The result is 968 square feet. The file does not print 22, 44, or 968. Arithmetic: 22 is not over 25, and 44 is not over 65, so the factory-approval sentence does not apply to this product.

Printed page 16 bases the unit price on track space times pool length, including steps, plus options. No deduction for steps is printed. No dollar amount is printed. A track space of 25 ft 6 in or more may require a larger main mechanism tube and a larger leading edge. That sentence is not the equal-to-25 cell. The same page lists other rows and prints no prices and no lead times: housing excavation, the 3 in drain, 3 in conduit for the hydraulic-unit housing, 1/2 in conduit, the dedicated GFCI, a concrete, gunite, or shotcrete box at a minimum of 6 in thick and 3500 PSI with no rebound, tile on the lower beam, track options, and the lid or bench. Those rows sit outside the square-foot product. The same lines, written so two bids can be compared, are the RFQ checklist.

When these lines do not apply

Printed page 2 places universal track and SnapTop on a deck that is already finished, on the deck surface. Flush track is for a new pool or a pool already built, set flush with the deck, and the sheet recommends it for indoor use only. A finished deck is an existing pool. The 6 in flush setback on printed page 4 stays with that track.

Printed page 14 is titled as the specifications review for Save-T covers. Its fabric weight, colors, and rope lines are that review. They are not a substitute for a blank Autosave cell. The cover of the file names both a Save-T 3 cover system and an Autosave spa cover. The box tables stay on their own pages.

Printed page 5 labels the electrical figures as minimum recommendations only. It requires local and federal codes, and it sends conduit details to the prewiring instructions. The repeated footer says the diagrams are general information and says to consult the installation instructions. The cover requires a contractor licensed and qualified in pool equipment where that jurisdiction has such a requirement. Where it does not, the cover requires a professional able to follow the instructions exactly.

File 800235 REL-0001, the owner manual, copyright 2020, opens on a different list. The marks are stainless steel cable, auto-shutoff, a CoverLink control pad, and a latching strap. That list records the installed unit. It does not size the box, and it prints no torque.

Method and sources

Updated October 2026. Lengths in the worked example are marked as arithmetic. An empty cell means the file prints no value there. Save-T 3 rows are not filled from Autosave rows.

The source PDF is Cover-Pools, General Information for Installing an Automatic Pool Cover, file 800024 Rel-0024, copyright 2015. Printed page 1: surfaces under 2 in, deck straps every 2 ft. Printed page 2: universal and SnapTop on a finished deck, flush track recommended for indoor use only. Printed page 3: true rectangle, 18 in over-dig, plumbing within 14 in of the deck, 3 in drain, 36 in and 16 in excavation from the waterline, motor on either end, no radius, no skimmer in the lowered wall. Printed page 4: flush track set back 6 in, universal track at the pool edge, no track on a skimmer lid. Printed page 5: 14 AWG under 50 ft, 12 AWG over 50 ft, 15 AMP dedicated G.F.C.I., 36 in flex, hydraulic motors above ground, two 1/2 in hoses over 80 ft. Printed page 7: Save-T 3 box rows and the call line. Printed pages 8 and 9: Autosave rows. Printed pages 11 and 12: cantilever, opening, and the coping note. Printed page 13: walk-on lid anchorage, tray maximum 24 in by 24 in. Printed page 14: fabric, power, and the safety note. Printed page 15: track space times pool length, over 25 ft or over 65 ft, maximum track space 36 ft. Printed page 16: cost rows with no dollar amount. The Big Red panel prints the torque figures. File 800235 REL-0001, copyright 2020, is used only for the installed-feature marks on its cover.

Questions

Can a landscape plan replace the cover sheet?
No. File 800024 does not list a landscape plan. Its sections are track, excavation and plumbing, electrical, mechanism housing, coping and deck, the recessed box cover, and the specifications review. A planting plan does not fill those lines.
Does an Autosave width fill a blank Save-T cell?
No. Printed pages 8 and 9 are the Autosave tables, for pools up to 13 ft or 200 square feet. Printed page 7 is the Save-T 3 underside table. A Save-T cell the sheet leaves empty stays empty. A standard Save-T 3 box length equal to 55 ft stays blank on printed page 7.

Parent hub: For Pool Builders