Updated October 2026

Pool Cover RFQ Checklist

Dropping the housing drain or the dedicated circuit from one bid is rework after the deck is poured. A pool cover RFQ checklist is the printed page 16 cost list from Cover-Pools file 800024 Rel-0024, copied in the same words on both bids, with no dollar amount filled in. A cell the sheet leaves blank stays blank on both bids.

Infographic titled Pool Cover RFQ Checklist, subtitle File 800024, page 16, with icons Scope, Track, Box, and Power, beside a pool rectangle labeled Housing, Bid A, Bid B, Same rows, and No price. No brand nameplate.
Schematic, not to scale.

Lines that make two bids comparable

Lines that make two bids comparable are the rows on printed page 16 of Cover-Pools file 800024 Rel-0024, together with the square-foot line on printed page 15. Pool builders copy those rows in the same words on both bids. The file is the 2015 installation overview for a Save-T 3 system or an Autosave spa cover. See automatic pool covers. Three lines are printed as standard and have no checkbox: Underside track or Universal track; an aluminum lid, a bench frame, or fiberglass ends; and a 110 V motor with a hard-wired 3-wire key. Every other row on printed page 16 is a checkbox. The file prints no dollar amount and no lead time on any row. The specification checklist is the sheet set those rows sit on. Construction coordination is the order the housing, the drain, and the power note have to be true before the next pour.

Rows both bids copy

Both bids copy the three standard lines and mark every checkbox. A checkbox marked on one bid and left empty on the other is not the same scope. Printed page 15 bases the product on track space times pool length. The motor mechanism in that pricing note is one foot from the pool edge, and the motor position is left or right. Printed page 12 states that the coping measurement is not the track space. How to measure a pool for an automatic cover holds the track-space pair. Pool cover coping integration holds the coping line. The figure names the six checkbox groups. It does not print a price.

Input or itemTypical value or sourceWhy it matters
File800024 Rel-0024, copyright 2015, Cover-PoolsThe installation overview this checklist copies
Standard track, printed page 16Underside track or Universal track. No checkboxThe baseline rail. Other rails are checkboxes
Standard housing, printed page 16Aluminum lid, bench frame, or fiberglass ends. No checkboxThe baseline lid line. Lid variants are checkboxes
Standard power, printed page 16110 V motor and hard-wired 3-wire key. No checkboxPrinted page 5 says 120V. This page does not equate the labels
Square-foot line, printed pages 15 and 16Track space times pool length, including steps, plus options. No dollar amount. No deduction for stepsThe product line. It is also a checkbox on page 16
Motor basis, printed page 15One foot from the pool edge. Left or rightBoth bids use this basis
Factory approval, printed page 15Track widths over 25 ft or lengths over 65 ft. Maximum track space 36 ftBoth bids carry this line when the bound is over
Track space equal to 25 ftThe approval sentence says over
Pool length equal to 65 ftThe approval sentence says over
Track space 25 ft 6 in or more, printed page 16Larger main mechanism tube and larger leading edgeA separate checkbox. Not the equal-to-25 cell
Electric run equal to 50 ftPrinted page 16 says over 50 ft
Electric run over 50 ft, printed page 16Heavy-gauge wire. No gauge is printed on this lineBoth bids copy the words and leave the gauge blank
Housing drain, printed page 163 in drain, drain to air or drain to pitA checkbox. No price
Concrete box, printed page 16Concrete, gunite, or shotcrete. Minimum 6 in thick. 3500 PSI. No reboundA checkbox. No price
Standard box length equal to 55 ftPrinted page 7 has under 55 and over 55. This page does not fill the equal case
Hose length equal to 80 ftPrinted page 5 says two 1/2 in hoses over 80 ft
Autosave over 13 ft, or over 200 square feetPrinted pages 8 and 9 have no row for that case
Six groups both bids copy from file 800024 page 16: Excavation, Electrical, Concrete, Track, Housing, and Power. Each card says Checkbox and No price. A note says three standard lines have no checkbox.
Schematic, not to scale.

Checkbox groups the file leaves unpriced

Each group below is a set of checkboxes on printed page 16. Both bids mark the same boxes. The file prints no dollar amount and no lead time in any group. The three standard lines in the table above are not in this list.

Checkbox groupRows the file printsPrice and lead time
Excavation and plumbingHousing excavation. 3 in drain, drain to air or drain to pit. 3 in conduit for the hydraulic-unit housingNone printed
Electrical1/2 in conduit for mechanism power. Electric run to the key switch. 15-amp GFCI dedicated circuit at the panel, 20 AMP for hydraulic. Electric runs over 50 ft require heavy-gauge wire. Electrical run for the accessory board. 1/2 in conduit for low-voltage wires, required with auto-shutoff or CoverLink wired controlsNone printed
ConcreteConcrete, gunite, or shotcrete box, minimum 6 in thick, 3500 PSI, no rebound. Additional deck around the housing. Tile on the lower beam, beam cover, or otherNone printed
Cover lineUnit price based on track space times pool length, including steps, plus options. Track space of 25 ft 6 in or more, larger main mechanism tube and larger leading edgeNone printed. No deduction for steps
Track checkboxesTrack channel for concrete or fiberglass pools, 2 or 3 sided. Flush. SnapTop. Vinyl-liner pool coping at 90°, 45°, 6 in radius, or 24 in radius. Track channel for vinyl-liner pools. Vanishing edge at 45° or 90°. Painted track extrusionsNone printed
Housing checkboxesPainted lid extrusions. Aluminum lids named Standard, Bezel, or Flush Mount. Walk-on Vanishing Lid trays. Bench for a deck-mounted mechanismNone printed. These rows are not the no-checkbox standard line
Power checkboxesAuto-shutoff control with amp limit. Wireless CoverLink touchpad. Wired CoverLink touchpad. Water-feature shutoff. Hydraulic pump with hydraulic hoses. Jandy iAquaLink interface and controlNone printed

What fails when one bid leaves a row off

Each miss is a row the file already prints. The prevention is the line both bids copy before the two numbers are set side by side.

Line left off one bidDominant failure modePrevention the sheet prints
Housing drain omittedWater stays in the recessed housingBoth bids name the 3 in drain, drain to air or drain to pit
Dedicated circuit omittedThe panel row is not the printed circuit15-amp GFCI dedicated at the panel. 20 AMP for hydraulic
Heavy-gauge cell filled with a gaugePrinted page 16 names no gauge, so the bids no longer share that conductor lineCopy heavy-gauge wire. Leave the gauge blank. A run equal to 50 ft stays blank
Steps deducted from pool lengthThe square-foot product shrinksInclude steps. The file prints no deduction
Equal to 25 ft filled from the over-25 sentenceThe blank boundary becomes a number one bid uses and the other does notLeave a track space equal to 25 ft blank. The maximum track space on the approval sentence is 36 ft
25 ft 6 in used as the equal-to-25 cellThe larger-tube checkbox disappearsCopy 25 ft 6 in as its own row
Flush compared with the Underside standard lineThe rail on one bid is a checkbox and the rail on the other is the standard lineMark Flush on both bids, or mark Underside or Universal on both
110 V written as the page 5 120V labelTwo printed labels become oneKeep 110 V on the page 16 standard line. Do not equate the labels
Walk-on tray written as the standard aluminum lidA housing checkbox takes the place of the no-checkbox standard lineStandard line: aluminum lid, bench frame, or fiberglass ends. The walk-on tray stays a checkbox
Concrete box omittedThe housing wall has no printed thickness and no printed strength on that bidMinimum 6 in thick, 3500 PSI, no rebound, on both bids

Square feet without a price

Cover square feet = track space x pool length. Printed page 15 states that product and prints no dollar amount. The pricing note puts the motor mechanism one foot from the pool edge, on the left or the right. The Undertrack diagram and the deck-mounted diagram on that page both use track space and pool length. Coping is not track space.

Rule of thumb. If track space is over 25 ft, or pool length is over 65 ft, both bids carry the factory-approval line, because printed page 15 requires factory approval there. The maximum track space on that sentence is 36 ft. If track space is equal to 25 ft, or pool length is equal to 65 ft, factory approval is required only above those thresholds.

Rule of thumb. If the electric run is over 50 ft, both bids copy the heavy-gauge sentence and leave the gauge blank. If the run is equal to 50 ft, follow the under-50-ft conductor schedule. Printed page 5 prints a wire size for under 50 ft and a different wire size for over 50 ft. Those sizes stay on the specification checklist and on electrical requirements. This page does not copy them into the page 16 cell.

Worked example. Printed page 15 does not print a sample pool. This checklist does not supply one. Arithmetic on the printed maximum: 36 is over 25, so a track space of 36 ft sits inside the factory-approval sentence. A track space equal to 25 ft does not. A pool length equal to 65 ft does not. The file does not print a pool length to multiply by 36, so this page does not compute a square-foot product from 36, and it does not print a price.

A track space of 25 ft 6 in is over 25 ft, so the approval sentence applies, and the larger-tube checkbox is a separate line. The file says a track space of 25 ft 6 in or more may require a larger main mechanism tube and a larger leading edge. Both bids copy that sentence. Neither bid turns it into a price.

The checkbox rows are the rest of the job, and they sit outside the square-foot product. Housing excavation, the 3 in drain, the 3 in conduit for the hydraulic-unit housing, both 1/2 in conduit lines, the dedicated circuit, the concrete box, tile on the lower beam, additional deck around the housing, the track checkboxes, and the lid and bench checkboxes have no price and no lead time on the page. Drainage requirements is the drain row. Pool cover boxes and housings is the concrete box. Lid options is the lid checkbox. Hydraulic system design is the hydraulic pump checkbox and the 3 in conduit. The figure is the equal cases both bids leave blank.

Equal cases left blank on both bids: 25 ft, 50 ft, 55 ft, 65 ft, 80 ft, and Autosave over 13 ft. Each value cell says Blank. A note says 25 ft 6 in is a separate row.
Schematic, not to scale.

When the standard line is the wrong row

The standard track line is Underside track or Universal track. Flush, SnapTop, a track channel, vinyl-liner coping, a vanishing edge, and painted extrusions are checkboxes. Printed page 2 says Flush is for new or existing pools, installed flush with the deck, and recommended for indoor use only. Universal track and SnapTop on that page are for existing decks. Both bids name the same one of those rows.

The standard power line is a 110 V motor and a hard-wired 3-wire key. A hydraulic pump with hydraulic hoses is a checkbox, and the panel line prints 20 AMP for hydraulic beside the 15-amp GFCI. A hose length equal to 80 ft stays blank, because printed page 5 says two 1/2 in hoses over 80 ft.

Printed page 14 names Slim among the track styles. Printed page 16 does not print a Slim checkbox. A Slim bid is not a page 16 track row. Request a dedicated line item from the supplier when specifying Slim track. The same page 14 note says a solid safety cover without a pump is not approved to ASTM F1346-91, and that an automatic water-removal cover pump is included. Printed page 16 does not print a price for that pump. Both bids follow the page 14 note or they are not the same scope.

Method and sources

Updated October 2026. An empty cell means the file prints no value there. A standard Save-T 3 box length equal to 55 ft stays blank. An Autosave pool over 13 ft, or over 200 square feet, has no row. The square-foot line is not turned into a price.

The source PDF is Cover-Pools, General Information for Installing an Automatic Pool Cover, file 800024 Rel-0024, copyright 2015. Printed page 15: track space times pool length, one foot from the pool edge, over 25 ft or over 65 ft, maximum track space 36 ft. Printed page 16: three standard lines and the cost-consideration checkboxes, with no dollar amount and no lead time. Printed page 12: the coping measurement is not the track space. Printed page 2: Flush is for new or existing pools and is installed flush with the deck; Universal and SnapTop are for existing decks. Printed page 5: the under-50 and over-50 wire sizes this page does not copy into the heavy-gauge cell, and two 1/2 in hoses over 80 ft. Printed page 7: the equal-to-55 ft box cell stays blank. Printed pages 8 and 9: no Autosave row over 13 ft or over 200 square feet. Printed page 14: Slim has no page 16 checkbox, and a solid safety cover without a pump is not approved to ASTM F1346-91.

Questions

Should I share one bidder's price with another?
No. Hand the next bidder the same checkbox list, not the number. Printed page 16 prints no dollar amount, so one bidder's number is not a line on the sheet. The next bid has to mark the same checkboxes: housing excavation, the 3 in drain, the dedicated circuit, the concrete box, the track checkboxes, and the lid or bench. A number without those rows hides the same rows on the next bid.
Does the square-foot line include housing excavation?
No. Housing excavation is its own checkbox on printed page 16. The square-foot line is track space times pool length, including steps, plus options. The file prints no dollar amount and no deduction for steps.
Does 25 ft 6 in fill the cell for 25 ft?
No. A track space equal to 25 ft stays blank. The sentence for 25 ft 6 in or more is a separate checkbox for a larger main mechanism tube and a larger leading edge.

Parent hub: For Pool Builders